Difference between revisions of "Annual guillotine checks"

From SSS Wiki
Jump to navigationJump to search
Line 1: Line 1:
 
To ensure continuous reliability, it is essential that the following procedure should be carried out at each annual guillotine check:
 
To ensure continuous reliability, it is essential that the following procedure should be carried out at each annual guillotine check:
  
−
    Cut cable with bolt cutters and withdraw through paying on gear
+
*Cut cable with bolt cutters and withdraw through paying on gear
−
    Hands clear!
+
*Hands clear!
−
    Operate guillotine
+
*Operate guillotine
−
    Check clearance between closed guillotine blades (should be < 0.005" or 0.013 mm). (Blade clearance may be adjusted by re-shimming.)
+
*Check clearance between closed guillotine blades (should be < 0.005" or 0.013 mm). (Blade clearance may be adjusted by re-shimming.)
−
    Support paying-on gear and remove six nuts and bolts
+
*Support paying-on gear and remove six nuts and bolts
−
    Remove paying on gear
+
*Remove paying on gear
−
    Remove assister springs
+
*Remove assister springs
−
    Remove guillotine actuating pivot bolt
+
*Remove guillotine actuating pivot bolt
−
    Remove four bolts securing cable guide
+
*Remove four bolts securing cable guide
−
    Remove remaining four bolts securing guillotine blade retaining slides
+
*Remove remaining four bolts securing guillotine blade retaining slides
−
    Carefully withdraw moving blade and coaxial spring assembly - take care with compressed springs
+
*Carefully withdraw moving blade and coaxial spring assembly - take care with compressed springs
−
    Clean all detritus from mechanism and springs
+
*Clean all detritus from mechanism and springs
−
    Clean and inspect all metal surfaces
+
*Clean and inspect all metal surfaces
−
    Check guillotine blades for damage and repair/replace if necessary
+
*Check guillotine blades for damage and repair/replace if necessary
−
    Lubricate springs and sliding surfaces with lithium based grease
+
*Lubricate springs and sliding surfaces with lithium based grease
−
    Replace everything but the paying in gear in reverse order. (The moving blade is replaced in a similar way to that used to load the guillotine)
+
*Replace everything but the paying in gear in reverse order. (The moving blade is replaced in a similar way to that used to load the guillotine)
−
    Load guillotine
+
*Load guillotine
−
    Thread two pieces of cable through the guillotine assembly
+
*Thread two pieces of cable through the guillotine assembly
−
    Hands clear!
+
*Hands clear!
−
    Fire guillotine - should cut two wires cleanly
+
*Fire guillotine - should cut two wires cleanly
−
    If OK - replace paying in gear and sign off
+
*If OK - replace paying in gear and sign off
−
    If not call AA
 
−
 
 
  
 
Equipment required:
 
Equipment required:

Revision as of 15:35, 19 May 2017

To ensure continuous reliability, it is essential that the following procedure should be carried out at each annual guillotine check:

  • Cut cable with bolt cutters and withdraw through paying on gear
  • Hands clear!
  • Operate guillotine
  • Check clearance between closed guillotine blades (should be < 0.005" or 0.013 mm). (Blade clearance may be adjusted by re-shimming.)
  • Support paying-on gear and remove six nuts and bolts
  • Remove paying on gear
  • Remove assister springs
  • Remove guillotine actuating pivot bolt
  • Remove four bolts securing cable guide
  • Remove remaining four bolts securing guillotine blade retaining slides
  • Carefully withdraw moving blade and coaxial spring assembly - take care with compressed springs
  • Clean all detritus from mechanism and springs
  • Clean and inspect all metal surfaces
  • Check guillotine blades for damage and repair/replace if necessary
  • Lubricate springs and sliding surfaces with lithium based grease
  • Replace everything but the paying in gear in reverse order. (The moving blade is replaced in a similar way to that used to load the guillotine)
  • Load guillotine
  • Thread two pieces of cable through the guillotine assembly
  • Hands clear!
  • Fire guillotine - should cut two wires cleanly
  • If OK - replace paying in gear and sign off

Equipment required:

Feeler gauges

Metric socket set and spanners

Releasing oil and small scraper/rags to clean mechanism and slides

Lub grease

Guillotine setting lever and pivot board.