Difference between revisions of "Annual guillotine checks"

From SSS Wiki
Jump to navigationJump to search
 
Line 1: Line 1:
 
To ensure continuous reliability, it is essential that the following procedure should be carried out at each annual guillotine check:
 
To ensure continuous reliability, it is essential that the following procedure should be carried out at each annual guillotine check:
  
−
*Cut cable with bolt cutters and withdraw through paying on gear
+
*Cut cable at first join with bolt cutters and withdraw through paying on gear
 
*Hands clear!
 
*Hands clear!
 
*Operate guillotine
 
*Operate guillotine
−
*Check clearance between closed guillotine blades (should be < 0.005" or 0.013 mm). (Blade clearance may be adjusted by re-shimming.)
+
*Check clearance between closed guillotine blades (should be < 0.005" or 0.013 mm). (Blade clearance may be adjusted using brass rubbing screws near bottom of blade guides.)
 
*Support paying-on gear and remove six nuts and bolts
 
*Support paying-on gear and remove six nuts and bolts
 
*Remove paying on gear
 
*Remove paying on gear
Line 11: Line 11:
 
*Remove four bolts securing cable guide
 
*Remove four bolts securing cable guide
 
*Remove remaining four bolts securing guillotine blade retaining slides
 
*Remove remaining four bolts securing guillotine blade retaining slides
−
*Carefully withdraw moving blade and coaxial spring assembly - take care with compressed springs
+
*Carefully withdraw removing moving blade and coaxial spring assembly - take care with compressed springs
−
*Clean all detritus from mechanism and springs
+
*Clean all detritus from mechanism especially any that could prevent full travel of guillotine blade
 
*Clean and inspect all metal surfaces
 
*Clean and inspect all metal surfaces
−
*Check guillotine blades for damage and repair/replace if necessary
+
*Check guillotine blades for damage/cracking and repair/replace if necessary
 
*Lubricate springs and sliding surfaces with lithium based grease
 
*Lubricate springs and sliding surfaces with lithium based grease
−
*Replace everything but the paying in gear in reverse order. (The moving blade is replaced in a similar way to that used to load the guillotine)
+
*Replace everything but the paying in gear in reverse order. (The moving blade is replaced in a similar way to that used to load the guillotine using a lvere to compress the springs)
 
*Load guillotine
 
*Load guillotine
 
*Thread two pieces of cable through the guillotine assembly
 
*Thread two pieces of cable through the guillotine assembly
Line 22: Line 22:
 
*Fire guillotine - should cut two wires cleanly
 
*Fire guillotine - should cut two wires cleanly
 
*If OK - replace paying in gear and sign off
 
*If OK - replace paying in gear and sign off
 +
*If not detailed analysis will be required.
  
 
Equipment required:
 
Equipment required:
Line 33: Line 34:
 
Lub grease
 
Lub grease
  
−
Guillotine setting lever and pivot board.
+
Guillotine setting equipment.

Latest revision as of 15:42, 19 May 2017

To ensure continuous reliability, it is essential that the following procedure should be carried out at each annual guillotine check:

  • Cut cable at first join with bolt cutters and withdraw through paying on gear
  • Hands clear!
  • Operate guillotine
  • Check clearance between closed guillotine blades (should be < 0.005" or 0.013 mm). (Blade clearance may be adjusted using brass rubbing screws near bottom of blade guides.)
  • Support paying-on gear and remove six nuts and bolts
  • Remove paying on gear
  • Remove assister springs
  • Remove guillotine actuating pivot bolt
  • Remove four bolts securing cable guide
  • Remove remaining four bolts securing guillotine blade retaining slides
  • Carefully withdraw removing moving blade and coaxial spring assembly - take care with compressed springs
  • Clean all detritus from mechanism especially any that could prevent full travel of guillotine blade
  • Clean and inspect all metal surfaces
  • Check guillotine blades for damage/cracking and repair/replace if necessary
  • Lubricate springs and sliding surfaces with lithium based grease
  • Replace everything but the paying in gear in reverse order. (The moving blade is replaced in a similar way to that used to load the guillotine using a lvere to compress the springs)
  • Load guillotine
  • Thread two pieces of cable through the guillotine assembly
  • Hands clear!
  • Fire guillotine - should cut two wires cleanly
  • If OK - replace paying in gear and sign off
  • If not detailed analysis will be required.

Equipment required:

Feeler gauges

Metric socket set and spanners

Releasing oil and small scraper/rags to clean mechanism and slides

Lub grease