Leading 5KVA Generator

Purchased 11/2010 from KMS Direct this is a standby generator to cover periods when the main Petter 17KVA Generator is unavailable. It is 'portable' to allow work such as welding etc. at locations remote from the main Petter 17KVA Generator. It may also be deployed to support catering for events such as 'Open Days'; 4.5 KW will easily power a microwave oven (1.8KW) and the Roundout Bus 230V lighting or heating, electric kettle, oven or boiling ring.


Service

Service interval 100 hours, see manual. For average use this equates to once per quarter in the Winter and once per six months in the Summer. Recommend end September, end December, end March.

Service notes (additional to manual)

  • Make sure air filter bolts are good and tight.
  • When changing oil lift unit up on blocks and insert pan underneath to catch oil.
  • Oil filter can be reused if not damaged. Wash in acetone when oil changed.

Leading LDE6800T Diesel Generator Specification

  • Rated Frequency: (Hz) 50
  • Rated Voltage (V): 230
  • Rated Current: (A) 19.6
  • Maximum Current (A): 21.7
  • Rated Output Power (kVA) 5.0
  • DC Output: 12 V/8.3A
  • Power Factor (cosφ): 1.0
  • Phase Number: Single phase
  • Coupling Mode: Rigid coupling by rotor drive shaft
  • Noise Level: [Db (A)@7m]: 69

ENGINE

  • Engine Model: LD186FAG
  • Engine Type: Single cylinder, 4-stroke, air-cooled, direct injection, diesel
  • Rated Rotation Speed: (rpm) 3,000
  • Rated Engine Power: [kW (HP)/rpm] 5.9(8.02) / 3,000
  • Displacement: [cc (cu.in)] 418(25.51)
  • Compression Ratio: 19:1

STRUCTURE

  • Structure Type: T: Silent type
  • Overall Dimension (mm/in) : 960x560x725(37.80x22.05x28.54)
  • Dry Weight: 165 lbs(363 Kgm)
  • Starting System: Electric starter
  • Rotation Direction: (Viewed From Flywheel) Clockwise
  • Fuel: 0#(summer), -10# (winter) light diesel oil (e.g. 'Red Diesel')
  • Lube Oil: SAE10W30 (above CC grade)
  • Low Oil Pressure Alert System: With

SAFETY

  • Ensure that either:
    • You are using 'double-insulated' tools or that,
    • The generator has the 'neutral phase' adequately bonded to earth
    • And that you are potected by an ELCB rated at <= 30mA.